Sign In | Join Free | My chinacsw.com
China Enviro Solutions Technology Co.,Ltd logo
Enviro Solutions Technology Co.,Ltd
We develops and produces gas analyzer and gas analysis system ranging from process gases and environmental emissions monitoring
Active Member

3 Years

Home > TDLAS Gas analyzer >

HCL / HF / NH3 TDLAS Gas analyzer Leak detection Safety 1ppm Resolution

Enviro Solutions Technology Co.,Ltd
Contact Now

HCL / HF / NH3 TDLAS Gas analyzer Leak detection Safety 1ppm Resolution

Brand Name : ESEGAS

Model Number : ESE-LASER-100

Product Name : TDLAS Gas Analysis System

Sampling Gas Temperature : ≥180℃

Resolution : 1ppm

Range : 10ppm/50ppm/200ppm/1000ppm

Measured Gas : NH3/HCL/HF

Gas Conditioning System : Yes

Sampling type : extractive type

Measurement Accuracy : 1%FS

Contact Now

TDLAS Gas Analyzer With Gas Conditioning System High Temperature Extraction Type Monitoring HCL/HF/NH3

TDLAS gas analyzer with gas conditioning system ESE-LASER-100 uses the whole process of high temperature combined heat extraction to monitor HCL/HF/NH3 gas in sample gas.The system consists of a sampling unit, a transmission unit, a preprocessing unit, a control unit, and an analysis unit. The analysis unit uses TDLAS technology.

Based on the principle of tunable laser absorption spectroscopy (TDLAS), laser gas analyzer scans and analyzes the gas absorption spectrum lines of specific wavelength, and realizes the gas concentration measurement by combining the digital lock-in amplifier and the advanced technology such as long path gas chamber. ESE-LASER series can realize high resolution, high precision, stable and reliable measurement of trace gases, and meet the requirements of process analysis and environmental detection.

Applications

☑ SCR, incineration & combustion processes

☑ Emission monitoring:Power generation, engine development, waste incineration furnaces, …

☑ Environmental monitoring: Landfill & green-house gases, livestock, …

☑ Chemical engineering: Production control & monitoring …

☑ Safety: Leak detection, refrigeration, toxic gases, .

☑ Climate control & monitoring: Livestock, climate chambers & rooms

Measured gas HCL/HF/NH3
Method Tunable Diode Laser Spectrometry (TDLAS)
Range HCL/HF: 0-50ppm,0-100ppm,0-500ppm( Customized)

NH3:Above 20ppm

Accuracy ± 1% full scale reading depending on integration stability (temperature & pressure)
Precision 1ppm
Displayed resolution 0.1ppm
Response time Less than 15S (at gas flow rate of 3 L/min)
Sampling Gas Temperature ≥180℃
Analog Output 4`20mA DC, Insulating output, maximum load is 900 ohm,
Digital Output RS232/485
Power Supply 90-240VAC / 50/60Hz 120W
Warm up time 30 minutes
Interface RS232
Ambient Temperature Temp:-10-50℃ Humidity:0-90%RH
Dimension 760(H)×500(L)×255(W)mm(analysis cabinet)

700(H)×450(L)×210(W)mm(control cabinet)


Product Tags:

NH3 TDLAS Gas Analyzer

      

TDLAS Gas Analyzer Leak Detection

      

Safety NH3 Analyzer

      
Quality HCL / HF / NH3 TDLAS Gas analyzer Leak detection Safety 1ppm Resolution for sale

HCL / HF / NH3 TDLAS Gas analyzer Leak detection Safety 1ppm Resolution Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Enviro Solutions Technology Co.,Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0